Export limit exceeded: 417953 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (417953 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2021-26280 | 2026-04-15 | 7.9 High | ||
| Locally installed application can bypass the permission check and perform system operations that require permission. | ||||
| CVE-2021-26281 | 2026-04-15 | 5.5 Medium | ||
| Some parameters of the alarm clock module are improperly stored, leaking some sensitive information. | ||||
| CVE-2021-26377 | 1 Amd | 11 Athlon, Athlon 3000, Radeon Instinct Mi25 and 8 more | 2026-04-15 | 4.1 Medium |
| Insufficient parameter validation while allocating process space in the Trusted OS (TOS) may allow for a malicious userspace process to trigger an integer overflow, leading to a potential denial of service. | ||||
| CVE-2021-26381 | 1 Amd | 17 Radeon Pro V520, Radeon Pro V620, Radeon Pro W5000 Series and 14 more | 2026-04-15 | N/A |
| Improper system call parameter validation in the Trusted OS may allow a malicious driver to perform mapping or unmapping operations on a large number of pages, potentially resulting in kernel memory corruption. | ||||
| CVE-2021-26383 | 1 Amd | 9 Instinct Mi210, Instinct Mi250, Radeon Pro V520 and 6 more | 2026-04-15 | 7.9 High |
| Insufficient bounds checking in AMD TEE (Trusted Execution Environment) could allow an attacker with a compromised userspace to invoke a command with malformed arguments leading to out of bounds memory access, potentially resulting in loss of integrity or availability. | ||||
| CVE-2021-26410 | 1 Amd | 15 Radeon Pro V520, Radeon Pro V620, Radeon Pro W5000 Series and 12 more | 2026-04-15 | N/A |
| Improper syscall input validation in ASP (AMD Secure Processor) may force the kernel into reading syscall parameter values from its own memory space allowing an attacker to infer the contents of the kernel memory leading to potential information disclosure. | ||||
| CVE-2021-27017 | 1 Puppet | 1 Puppet Agent | 2026-04-15 | 6.6 Medium |
| Utilization of a module presented a security risk by allowing the deserialization of untrusted/user supplied data. This is resolved in the Puppet Agent 7.4.0 release. | ||||
| CVE-2021-27289 | 2026-04-15 | 9.1 Critical | ||
| A replay attack vulnerability was discovered in a Zigbee smart home kit manufactured by Ksix (Zigbee Gateway Module = v1.0.3, Door Sensor = v1.0.7, Motion Sensor = v1.0.12), where the Zigbee anti-replay mechanism - based on the frame counter field - is improperly implemented. As a result, an attacker within wireless range can resend captured packets with a higher sequence number, which the devices incorrectly accept as legitimate messages. This allows spoofed commands to be injected without authentication, triggering false alerts and misleading the user through notifications in the mobile application used to monitor the network. | ||||
| CVE-2021-27961 | 2026-04-15 | 6.5 Medium | ||
| evesys 7.1 (2152) through 8.0 (2202) allows Reflected XSS via the indexeva.php action parameter. | ||||
| CVE-2021-32007 | 1 Secomea | 1 Gatemanager | 2026-04-15 | 3.5 Low |
| This issue affects: Secomea GateManager Version 9.5 and all prior versions. Protection Mechanism Failure vulnerability in web server of Secomea GateManager to potentially leak information to remote servers. | ||||
| CVE-2021-35402 | 1 Prolink | 1 Prc2402m | 2026-04-15 | 10 Critical |
| PROLiNK PRC2402M 20190909 before 2021-06-13 allows live_api.cgi?page=satellite_list OS command injection via shell metacharacters in the ip parameter (for satellite_status). | ||||
| CVE-2021-40959 | 2026-04-15 | 6.1 Medium | ||
| A reflected cross-site scripting vulnerability in MONITORAPP Application Insight Web Application Firewall (AIWAF) <= 4.1.6 and <=5.0 was identified on the subpage `/process_management/process_status.xhr.php`. This vulnerability allows an attacker to inject malicious scripts that execute in the context of the victim's session. | ||||
| CVE-2021-41528 | 2026-04-15 | N/A | ||
| An error when handling authorization related to the import / export interfaces on the RISC Platform prior to the saas-2021-12-29 release can potentially be exploited to access the import / export functionality with low privileges. | ||||
| CVE-2021-41527 | 2026-04-15 | N/A | ||
| An error related to the 2-factor authorization (2FA) on the RISC Platform prior to the saas-2021-12-29 release can potentially be exploited to bypass the 2FA. The vulnerability requires that the 2FA setup hasn’t been completed. | ||||
| CVE-2021-41719 | 2026-04-15 | 7.5 High | ||
| Maharashtra State Electricity Distribution Company Limited Mahavitran IOS Application 16.1 application till version 16.1 communicates using the GET method to process requests that contain sensitive information such as user account name and password, which can expose that information through the browser's history, referrers, web logs, and other sources. | ||||
| CVE-2021-42718 | 1 Replicated | 1 Replicated Classic | 2026-04-15 | 4.9 Medium |
| Information Disclosure in API in Replicated Replicated Classic versions prior to 2.53.1 on all platforms allows authenticated users with Admin Console access to retrieve sensitive data, including application secrets, via accessing container definitions with environment variables through the Admin Console API on port 8800. This CVE was originally reserved in 2021 and later publicly disclosed by Replicated on their website on 21 October 2021. However, it mistakenly remained in the Reserved But Public (RBP) status with the CVE Numbering Authority (CNA). Please note that this product reached its end of life on 31 December 2024. Publishing this CVE with the CNA was required to comply with CNA rules, despite the fact that the issue was disclosed and fixed four years ago, and the affected product is no longer supported as of 2024. Summary of VulnerabilityThis advisory discloses a low severity security vulnerability in the versions of Replicated Classic listed above (“Affected Replicated Classic Versions”) DescriptionReplicated Classic versions prior to 2.53.1 have an authenticated API from the Replicated Admin Console that may expose sensitive data including application secrets, depending on how the application manifests are written. A user with valid credentials and access to the Admin Console port (8800) on the Replicated Classic server can retrieve container definitions including environment variables which may contain passwords and other secrets depending on how the application is configured. This data is shared over authenticated sessions to the Admin Console only, and was never displayed or used in the application processing. To remediate this issue, we removed the sensitive data from the API, sending only the data to the Admin Console that was needed. TimelineThis issue was discovered during a security review on 16 September 2021. Patched versions were released on 23 September 2021. This advisory was published on 21 October 2021. The CVE Numbering Authority (CNA) notified Replicated on 23 January 2025 that the CVE was still in Reserved But Public (RBP) status. Upon discovering the oversight in updating the status to published with the CNA, Replicated submitted the updated report on the same day, 23 January 2025. | ||||
| CVE-2021-43768 | 1 Malwarebytes | 1 Malwarebytes | 2026-04-15 | 5.3 Medium |
| In Malwarebytes For Teams v.1.0.990 and before and fixed in v.1.0.1003 and later a privilege escalation can occur via the COM interface running in mbamservice.exe. | ||||
| CVE-2021-4455 | 2026-04-15 | 9.8 Critical | ||
| The Wordpress Plugin Smart Product Review plugin for WordPress is vulnerable to arbitrary file uploads due to missing file type validation in all versions up to, and including, 1.0.4. This makes it possible for unauthenticated attackers to upload arbitrary files on the affected site's server which may make remote code execution possible. | ||||
| CVE-2021-4459 | 1 Sma | 8 Sunny Boy, Sunny Boy 1.5, Sunny Boy 2.5 and 5 more | 2026-04-15 | 6.5 Medium |
| An authorized remote attacker can access files and directories outside the intended web root, potentially exposing sensitive system information of the affected Sunny Boy devices. | ||||
| CVE-2021-4461 | 1 Seeyon | 1 Zhiyuan Oa Web Application System | 2026-04-15 | N/A |
| Seeyon Zhiyuan OA Web Application System versions up to and including 7.0 SP1 improperly decode and parse the `enc` parameter in thirdpartyController.do. The decoded map values can influence session attributes without sufficient authentication/authorization checks, enabling attackers to assign a session to arbitrary user IDs. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-30 at 00:30:40.855917 UTC. | ||||