Export limit exceeded: 55985 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (55985 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-8101 | 1 Linkify | 1 Linkify | 2026-04-15 | 8.6 High |
| Improperly Controlled Modification of Object Prototype Attributes ('Prototype Pollution') vulnerability in Linkify (linkifyjs) allows XSS Targeting HTML Attributes and Manipulating User-Controlled Variables.This issue affects Linkify: from 4.3.1 before 4.3.2. | ||||
| CVE-2025-10259 | 1 Mitsubishi | 1 Melsec Iq-f Series | 2026-04-15 | 5.3 Medium |
| Improper Validation of Specified Quantity in Input vulnerability in TCP Communication Function on Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote attacker to disconnect the connection by sending specially crafted TCP packets to cause a denial-of-service (DoS) condition on the products. There is no impact on connections other than the attacked one. | ||||
| CVE-2025-2401 | 2026-04-15 | N/A | ||
| Buffer overflow vulnerability in Immunity Debugger affecting version 1.85, its exploitation could allow a local attacker to execute arbitrary code, due to the lack of proper boundary checking. | ||||
| CVE-2025-30089 | 2026-04-15 | 5.4 Medium | ||
| gurk (aka gurk-rs) through 0.6.3 mishandles ANSI escape sequences. | ||||
| CVE-2025-41426 | 2026-04-15 | 9.8 Critical | ||
| Affected Vertiv products contain a stack based buffer overflow vulnerability. An attacker could exploit this vulnerability to gain code execution on the device. | ||||
| CVE-2025-11743 | 1 Rockwellautomation | 1 Compactlogix 5370 | 2026-04-15 | N/A |
| A denial-of-service security issue in the affected product. The security issue occurs when a malformed CIP forward open message is sent. This could result in a major nonrecoverable fault a restart is required to recover. | ||||
| CVE-2024-0119 | 1 Nvidia | 3 Cloud Gaming Guest, Gpu Display Driver, Virtual Gpu | 2026-04-15 | 7.8 High |
| NVIDIA GPU Display Driver for Windows contains a vulnerability in the user mode layer, where an unprivileged regular user can cause an out-of-bounds read. A successful exploit of this vulnerability might lead to code execution, denial of service, escalation of privileges, information disclosure, and data tampering. | ||||
| CVE-2024-6352 | 2026-04-15 | 4.3 Medium | ||
| A malformed packet can cause a buffer overflow in the APS layer of the Ember ZNet stack and lead to an assert | ||||
| CVE-2024-13893 | 2026-04-15 | N/A | ||
| Smartwares cameras CIP-37210AT and C724IP, as well as others which share the same firmware in versions up to 3.3.0, might share same credentials for telnet service. Hash of the password can be retrieved through physical access to SPI connected memory. For the telnet service to be enabled, the inserted SD card needs to have a folder with a specific name created. Two products were tested, but since the vendor has not replied to reports, patching status remains unknown, as well as groups of devices and firmware ranges in which the same password is shared. Newer firmware versions might be vulnerable as well. | ||||
| CVE-2025-0638 | 1 Nlnetlabs | 1 Routinator | 2026-04-15 | 7.5 High |
| The initial code parsing the manifest did not check the content of the file names yet later code assumed that it was checked and panicked when encountering illegal characters, resulting in a crash of Routinator. | ||||
| CVE-2025-20623 | 1 Redhat | 6 Enterprise Linux, Rhel Aus, Rhel E4s and 3 more | 2026-04-15 | 5.6 Medium |
| Exposure of sensitive information caused by shared microarchitectural predictor state that influences transient execution for some Intel(R) Core™ processors (10th Generation) may allow an authenticated user to potentially enable information disclosure via local access. | ||||
| CVE-2025-10207 | 1 Abb | 1 Flxeon | 2026-04-15 | 7.2 High |
| Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5. | ||||
| CVE-2025-11010 | 1 Vstakhov | 1 Libucl | 2026-04-15 | 5.3 Medium |
| A vulnerability has been found in vstakhov libucl up to 0.9.2. Affected by this vulnerability is the function ucl_include_common of the file /src/ucl_util.c. Such manipulation leads to heap-based buffer overflow. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2025-31930 | 2026-04-15 | 8.8 High | ||
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger. | ||||
| CVE-2025-31929 | 2026-04-15 | 4.2 Medium | ||
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code. | ||||
| CVE-2024-36578 | 1 Akbr | 1 Update | 2026-04-15 | 5.9 Medium |
| akbr update 1.0.0 is vulnerable to Prototype Pollution via update/index.js. | ||||
| CVE-2020-37193 | 2 Krylack, Top Password Software | 2 Zip Password Recovery, Zip Password Recovery | 2026-04-15 | 7.5 High |
| ZIP Password Recovery 2.30 contains a denial of service vulnerability that allows attackers to crash the application by providing maliciously crafted input. Attackers can create a specially prepared text file with specific characters to trigger an application crash when selecting a ZIP file. | ||||
| CVE-2024-28042 | 2026-04-15 | 8.4 High | ||
| SUBNET Solutions Inc. has identified vulnerabilities in third-party components used in PowerSYSTEM Center. | ||||
| CVE-2020-37195 | 1 Nsasoft | 2 Blueauditor, Spotauditor | 2026-04-15 | 7.5 High |
| BlueAuditor 1.7.2.0 contains a denial of service vulnerability in the registration name input field that allows attackers to crash the application. Attackers can generate a 1000-character buffer payload and paste it into the 'Name' field to trigger an application crash. | ||||
| CVE-2024-27629 | 1 Rordenlab | 1 Dcm2niix | 2026-04-15 | 7.8 High |
| An issue in dc2niix before v.1.0.20240202 allows a local attacker to execute arbitrary code via the generated file name is not properly escaped and injected into a system call when certain types of compression are used. | ||||