Search Results (1966 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2023-40901 1 Tenda 3 Ac10, Ac10v4, Ac10v4 Firmware 2024-10-02 9.8 Critical
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg.
CVE-2023-40902 1 Tenda 2 Ac10v4, Ac10v4 Firmware 2024-10-02 9.8 Critical
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
CVE-2023-40797 1 Tenda 2 Ac23, Ac23 Firmware 2024-10-02 8.8 High
In Tenda AC23 v16.03.07.45_cn, the sub_4781A4 function does not validate the parameters entered by the user, resulting in a post-authentication stack overflow vulnerability.
CVE-2023-40915 1 Tenda 2 Ax3, Ax3 Firmware 2024-10-02 7.5 High
Tenda AX3 v16.03.12.11 has a stack buffer overflow vulnerability detected at function form_fast_setting_wifi_set. This vulnerability allows attackers to cause a Denial of Service (DoS) via the ssid parameter.
CVE-2023-40798 1 Tenda 2 Ac23, Ac23 Firmware 2024-10-02 8.8 High
In Tenda AC23 v16.03.07.45_cn, the formSetIPv6status and formGetWanParameter functions do not authenticate user input parameters, resulting in a post-authentication stack overflow vulnerability.
CVE-2023-40799 1 Tenda 2 Ac23, Ac23 Firmware 2024-10-02 9.8 Critical
Tenda AC23 Vv16.03.07.45_cn is vulnerable to Buffer Overflow via sub_450A4C function.
CVE-2023-40800 1 Tenda 2 Ac23, Ac23 Firmware 2024-10-02 8.8 High
The compare_parentcontrol_time function does not authenticate user input parameters, resulting in a post-authentication stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn.
CVE-2023-40801 1 Tenda 2 Ac23, Ac23 Firmware 2024-10-02 8.8 High
The sub_451784 function does not validate the parameters entered by the user, resulting in a stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn
CVE-2023-40802 1 Tenda 2 Ac23, Ac23 Firmware 2024-10-02 6.5 Medium
The get_parentControl_list_Info function does not verify the parameters entered by the user, causing a post-authentication heap overflow vulnerability in Tenda AC23 v16.03.07.45_cn
CVE-2023-40846 1 Tenda 2 Ac6, Ac6 Firmware 2024-10-02 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function sub_90998.
CVE-2023-40847 1 Tenda 2 Ac6, Ac6 Firmware 2024-10-02 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via the function "initIpAddrInfo." In the function, it reads in a user-provided parameter, and the variable is passed to the function without any length check.
CVE-2023-40848 1 Tenda 2 Ac6, Ac6 Firmware 2024-10-02 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via the function "sub_7D858."
CVE-2023-51958 1 Tenda 2 Ax1803, Ax1803 Firmware 2024-10-01 9.8 Critical
Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function formGetIptv.
CVE-2024-7151 1 Tenda 2 O3, O3 Firmware 2024-10-01 8.8 High
A vulnerability was found in Tenda O3 1.0.0.10(2478). It has been declared as critical. This vulnerability affects the function fromMacFilterSet of the file /goform/setMacFilter. The manipulation of the argument remark leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-272554 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-40837 1 Tenda 2 Ac6, Ac6 Firmware 2024-10-01 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_ADD50' contains a command execution vulnerability. In the "formSetIptv" function, obtaining the "list" and "vlanId" fields, unfiltered passing these two fields as parameters to the "sub_ADD50" function to execute commands.
CVE-2023-40838 1 Tenda 2 Ac6, Ac6 Firmware 2024-10-01 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_3A1D0' contains a command execution vulnerability.
CVE-2023-40839 1 Tenda 2 Ac6, Ac6 Firmware 2024-10-01 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_ADF3C' contains a command execution vulnerability. In the "formSetIptv" function, obtaining the "list" and "vlanId" fields, unfiltered passing these two fields as parameters to the "sub_ADF3C" function to execute commands.
CVE-2023-40840 1 Tenda 2 Ac6, Ac6 Firmware 2024-10-01 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "fromGetWirelessRepeat."
CVE-2023-40841 1 Tenda 2 Ac6, Ac6 Firmware 2024-10-01 9.8 Critical
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "add_white_node,"
CVE-2023-40842 1 Tenda 2 Ac6, Ac6 Firmware 2024-10-01 9.8 Critical
Tengda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function "R7WebsSecurityHandler."