Search Results (1966 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-10283 1 Tenda 3 Rx9, Rx9 Pro, Rx9 Pro Firmware 2024-11-01 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10280 1 Tenda 20 Ac10, Ac10 Firmware, Ac10u and 17 more 2024-11-01 6.5 Medium
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10281 1 Tenda 3 Rx9, Rx9 Pro, Rx9 Pro Firmware 2024-11-01 8.8 High
A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10282 1 Tenda 3 Rx9, Rx9 Pro, Rx9 Pro Firmware 2024-11-01 8.8 High
A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-10130 1 Tenda 2 Ac8, Ac8 Firmware 2024-10-28 8.8 High
A vulnerability classified as critical was found in Tenda AC8 16.03.34.06. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-10123 1 Tenda 2 Ac8, Ac8 Firmware 2024-10-28 8.8 High
A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compare_parentcontrol_time of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This is not the same issue like CVE-2023-33671. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-39784 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2024-10-04 7.5 High
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the save_virtualser_data function.
CVE-2023-39785 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2024-10-04 7.5 High
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the list parameter in the set_qosMib_list function.
CVE-2023-39786 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2024-10-04 7.5 High
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sscanf function.
CVE-2024-46628 2 Tenda, Tendacn 3 G3 Firmware, G3, G3 Firmware 2024-10-04 8 High
Tenda G3 Router firmware v15.03.05.05 was discovered to contain a remote code execution (RCE) vulnerability via the usbPartitionName parameter in the formSetUSBPartitionUmount function.
CVE-2023-40891 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2024-10-03 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter firewallEn at /goform/SetFirewallCfg.
CVE-2023-40892 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2024-10-03 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter schedStartTime and schedEndTime at /goform/openSchedWifi.
CVE-2023-40893 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2024-10-03 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet.
CVE-2023-40894 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2024-10-03 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetStaticRouteCfg.
CVE-2023-40895 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2024-10-03 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg.
CVE-2023-40896 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2024-10-03 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list and bindnum at /goform/SetIpMacBind.
CVE-2023-40897 1 Tenda 2 Ac8v4, Ac8v4 Firmware 2024-10-03 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter mac at /goform/GetParentControlInfo.
CVE-2023-40898 1 Tenda 3 Ac8, Ac8v4, Ac8v4 Firmware 2024-10-03 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter timeZone at /goform/SetSysTimeCfg.
CVE-2023-40899 1 Tenda 3 Ac8, Ac8v4, Ac8v4 Firmware 2024-10-03 9.8 Critical
Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.
CVE-2023-40904 1 Tenda 2 Ac10v4, Ac10v4 Firmware 2024-10-02 9.8 Critical
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at /goform/setMacFilterCfg.