Search Results (2523 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2023-1966 1 Illumina 22 Iscan, Iscan Firmware, Iseq 100 and 19 more 2025-01-16 7.4 High
Instruments with Illumina Universal Copy Service v1.x and v2.x contain an unnecessary privileges vulnerability. An unauthenticated malicious actor could upload and execute code remotely at the operating system level, which could allow an attacker to change settings, configurations, software, or access sensitive data on the affected product.
CVE-2023-1944 1 Kubernetes 1 Minikube 2025-01-16 8.4 High
This vulnerability enables ssh access to minikube container using a default password.
CVE-2025-0518 2025-01-16 N/A
Unchecked Return Value, Out-of-bounds Read vulnerability in FFmpeg allows Read Sensitive Constants Within an Executable. This vulnerability is associated with program files https://github.Com/FFmpeg/FFmpeg/blob/master/libavfilter/af_pan.C . This issue affects FFmpeg: 7.1. Issue was fixed:  https://github.com/FFmpeg/FFmpeg/commit/b5b6391d64807578ab872dc58fb8aa621dcfc38a https://github.com/FFmpeg/FFmpeg/commit/b5b6391d64807578ab872dc58fb8aa621dcfc38a This issue was discovered by: Simcha Kosman
CVE-2002-1372 3 Apple, Debian, Redhat 4 Cups, Mac Os X, Debian Linux and 1 more 2025-01-16 7.5 High
Common Unix Printing System (CUPS) 1.1.14 through 1.1.17 does not properly check the return values of various file and socket operations, which could allow a remote attacker to cause a denial of service (resource exhaustion) by causing file descriptors to be assigned and not released, as demonstrated by fanta.
CVE-2023-2881 1 Pimcore 1 Customer-data-framework 2025-01-16 4.9 Medium
Storing Passwords in a Recoverable Format in GitHub repository pimcore/customer-data-framework prior to 3.3.10.
CVE-2014-2264 1 Synology 1 Diskstation Manager 2025-01-14 N/A
The OpenVPN module in Synology DiskStation Manager (DSM) 4.3-3810 update 1 has a hardcoded root password of synopass, which makes it easier for remote attackers to obtain access via a VPN session.
CVE-2024-35783 1 Siemens 6 Simatic Batch, Simatic Information Server, Simatic Pcs7 and 3 more 2025-01-14 9.1 Critical
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges.
CVE-2022-46142 1 Siemens 202 Ruggedcom Rm1224 Lte\(4g\) Eu, Ruggedcom Rm1224 Lte\(4g\) Eu Firmware, Ruggedcom Rm1224 Lte\(4g\) Nam and 199 more 2025-01-14 5.7 Medium
Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords.
CVE-2024-28010 1 Nec 28 Aterm W1200ex-ms Firmware, Aterm Wf300hp2 Firmware, Aterm Wf300hp Firmware and 25 more 2025-01-14 9.8 Critical
Use of Hard-coded Password in NEC Corporation Aterm WG1800HP4, WG1200HS3, WG1900HP2, WG1200HP3, WG1800HP3, WG1200HS2, WG1900HP, WG1200HP2, W1200EX(-MS), WG1200HS, WG1200HP, WF300HP2, W300P, WF800HP, WR8165N, WG2200HP, WF1200HP2, WG1800HP2, WF1200HP, WG600HP, WG300HP, WF300HP, WG1800HP, WG1400HP, WR8175N, WR9300N, WR8750N, WR8160N, WR9500N, WR8600N, WR8370N, WR8170N, WR8700N, WR8300N, WR8150N, WR4100N, WR4500N, WR8100N, WR8500N, CR2500P, WR8400N, WR8200N, WR1200H, WR7870S, WR6670S, WR7850S, WR6650S, WR6600H, WR7800H, WM3400RN, WM3450RN, WM3500R, WM3600R, WM3800R, WR8166N, MR01LN MR02LN, WG1810HP(JE) and WG1810HP(MF) all versions allows a attacker to execute an arbitrary OS command via the internet.
CVE-2024-28005 2025-01-14 4.7 Medium
Aterm WG1800HP4, WG1200HS3, WG1900HP2, WG1200HP3, WG1800HP3, WG1200HS2, WG1900HP, WG1200HP2, W1200EX(-MS), WG1200HS, WG1200HP, WF300HP2, W300P, WF800HP, WR8165N, WG2200HP, WF1200HP2, WG1800HP2, WF1200HP, WG600HP, WG300HP, WF300HP, WG1800HP, WG1400HP, WR8175N, WR9300N, WR8750N, WR8160N, WR9500N, WR8600N, WR8370N, WR8170N, WR8700N, WR8300N, WR8150N, WR4100N, WR4500N, WR8100N, WR8500N, CR2500P, WR8400N, WR8200N, WR1200H, WR7870S, WR6670S, WR7850S, WR6650S, WR6600H, WR7800H, WM3400RN, WM3450RN, WM3500R, WM3600R, WM3800R, WR8166N, MR01LN MR02LN, WG1810HP(JE) and WG1810HP(MF) all versions allows a attacker who has obtained high privileges can execute arbitrary scripts.
CVE-2021-47047 1 Linux 1 Linux Kernel 2025-01-10 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: spi: spi-zynqmp-gqspi: return -ENOMEM if dma_map_single fails The spi controller supports 44-bit address space on AXI in DMA mode, so set dma_addr_t width to 44-bit to avoid using a swiotlb mapping. In addition, if dma_map_single fails, it should return immediately instead of continuing doing the DMA operation which bases on invalid address. This fixes the following crash which occurs in reading a big block from flash: [ 123.633577] zynqmp-qspi ff0f0000.spi: swiotlb buffer is full (sz: 4194304 bytes), total 32768 (slots), used 0 (slots) [ 123.644230] zynqmp-qspi ff0f0000.spi: ERR:rxdma:memory not mapped [ 123.784625] Unable to handle kernel paging request at virtual address 00000000003fffc0 [ 123.792536] Mem abort info: [ 123.795313] ESR = 0x96000145 [ 123.798351] EC = 0x25: DABT (current EL), IL = 32 bits [ 123.803655] SET = 0, FnV = 0 [ 123.806693] EA = 0, S1PTW = 0 [ 123.809818] Data abort info: [ 123.812683] ISV = 0, ISS = 0x00000145 [ 123.816503] CM = 1, WnR = 1 [ 123.819455] user pgtable: 4k pages, 48-bit VAs, pgdp=0000000805047000 [ 123.825887] [00000000003fffc0] pgd=0000000803b45003, p4d=0000000803b45003, pud=0000000000000000 [ 123.834586] Internal error: Oops: 96000145 [#1] PREEMPT SMP
CVE-2023-24825 1 Riot-os 1 Riot 2025-01-10 7.5 High
RIOT-OS, an operating system for Internet of Things (IoT) devices, contains a network stack with the ability to process 6LoWPAN frames. Prior to version 2023.04, an attacker can send a crafted frame to the device to trigger a NULL pointer dereference leading to denial of service. This issue is fixed in version 2023.04. There are no known workarounds.
CVE-2023-3013 1 Gpac 1 Gpac 2025-01-09 7.1 High
Unchecked Return Value in GitHub repository gpac/gpac prior to 2.2.2.
CVE-2024-25967 1 Dell 1 Powerscale Onefs 2025-01-09 6.7 Medium
Dell PowerScale OneFS versions 8.2.x through 9.7.0.1 contains an execution with unnecessary privileges vulnerability. A local high privileged attacker could potentially exploit this vulnerability, leading to escalation of privileges.
CVE-2024-43651 2025-01-09 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-43659 2025-01-09 7.2 High
After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2025-01-09 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43653 2025-01-09 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43652 2025-01-09 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43649 2025-01-09 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).