| A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior) |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution or the crash of HTTPs stack which is used for the device Web HMI. Affected Products: Easergy P5 (V01.401.102 and prior) |
| A Permissions, Privileges, and Access Control vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to overwrite the original password with their password. If an attacker exploits this vulnerability and overwrite the password, the attacker can upload the original program from the PLC. |
| Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request. |
| A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of the shell meta characters with the value of 'system.download.sd_file' |
| The vulnerability exists within processing of sendmail.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The applet allows callers to select arbitrary files to send to an arbitrary email address. |
| A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior) |
| A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior) |
| Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible. |
| An exposure of sensitive information vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. Using a directory traversal attack, an unauthorized person can view web server files. |
| The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service (resource consumption) via unspecified vectors. NOTE: the vendor reportedly disputes this issue because it "could not be duplicated" and "an attacker could not remotely exploit this observed behavior to deny PLC control functions. |
| The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. A remote, authenticated attacker can exploit this vulnerability by sending a crafted request to the target server. |
| A security misconfiguration vulnerability exists in Schneider Electric's IGSS Mobile application versions 3.01 and prior in which a lack of certificate pinning during the TLS/SSL connection establishing process can result in a man-in-the-middle attack. |
| A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67. |
| A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server components. |
| In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request. |
| The vulnerability exists within processing of editobject.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the type input parameter. |
| The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918. |
| A CWE-269: Improper Privilege Management vulnerability exists that could allow elevated functionality when guessing credentials. Affected Products: Acti9 PowerTag Link C (A9XELC10-A) (V1.7.5 and prior), Acti9 PowerTag Link C (A9XELC10-B) (V2.12.0 and prior) |
| In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts. |