| A vulnerability in the “Backup & Restore” functionality of the web application of ctrlX OS allows a remote authenticated (lowprivileged) attacker to access secret information via multiple crafted HTTP requests. |
| Incorrect Permission Assignment for Critical Resource, Cleartext Storage of Sensitive Information vulnerability in ABB Automation Builder.This issue affects Automation Builder: through 2.8.0. |
| An issue was discovered on goTenna Mesh devices with app 5.5.3 and firmware 1.1.12. By default, a GID is the user's phone number unless they specifically opt out. A phone number is very sensitive information because it can be tied back to individuals. The app does not encrypt the GID in messages. |
| An issue was discovered on goTenna v1 devices with app 5.5.3 and firmware 0.25.5. By default, the GID is the user's phone number unless they specifically opt out. A phone number is very sensitive information because it can be tied back to individuals. The app does not encrypt the GID in messages. |
| An issue was discovered on goTenna v1 devices with app 5.5.3 and firmware 0.25.5. A command channel includes the next hop. which can be intercepted and used to break frequency hopping. |
|
IBM Security Guardium 10.5, 10.6, 11.0, 11.1, 11.2, 11.3, and 11.4 stores user credentials in plain clear text which can be read by a local privileged user. IBM X-Force ID: 215587.
|
| Cleartext Transmission of Sensitive Information vulnerability due to the use of Basic Authentication for HTTP connections in Mitsubishi Electric consumer electronics products (PHOTOVOLTAIC COLOR MONITOR ECO-GUIDE, HEMS adapter, Wi-Fi Interface, Air Conditioning, Induction hob, Mitsubishi Electric HEMS Energy Measurement Unit, Refrigerator, Remote control with Wi-Fi Interface, BATHROOM THERMO VENTILATOR, Rice cooker, Mitsubishi Electric HEMS control adapter, Energy Recovery Ventilator, Smart Switch, Ventilating Fan, Range hood fan, Energy Measurement Unit and Air Purifier) allows a remote unauthenticated attacker to disclose information in the products or cause a denial of service (DoS) condition as a result by sniffing credential information (username and password).
The wide range of models/versions of Mitsubishi Electric consumer electronics products are affected by this vulnerability.
As for the affected product models/versions, see the Mitsubishi Electric's advisory which is listed in [References] section.
|
| UPSMON PRO transmits sensitive data in cleartext over HTTP protocol. An unauthenticated remote attacker can exploit this vulnerability to access sensitive data. |
| A flaw was found in moodle. The cURL wrapper in Moodle strips HTTPAUTH and USERPWD headers during emulated redirects, but retains other original request headers, so HTTP authorization header information could be unintentionally sent in requests to redirect URLs. |
| A flaw was found in moodle. Some hidden user profile fields are visible in gradebook reports, which could result in users without the "view hidden user fields" capability having access to the information. |
| LOYTEC LINX-151, LINX-212, LVIS-3ME12-A1, LIOB-586, LIOB-580 V2, LIOB-588, L-INX Configurator devices (all versions) send password-change requests via cleartext HTTP. |
| A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy’s PCM600 product included in the versions listed below, where IEDs credentials are stored in a cleartext format in the PCM600 database and logs files. An attacker having get access to the exported backup file can exploit the vulnerability and obtain user credentials of the IEDs. Additionally, an attacker with administrator access to the PCM600 host machine can obtain other user credentials by analyzing database log files. The credentials may be used to perform unauthorized modifications such as loading incorrect configurations, reboot the IEDs or cause a denial-of-service on the IEDs. |
| Insecure key exchange between Delinea PAM Secret Server 11.4 and the Distributed Engine 8.4.3 allows a PAM administrator to obtain the Symmetric Key (used to encrypt RabbitMQ messages) via crafted payloads to the /pre-authenticate, /authenticate, and /execute-and-respond REST API endpoints. This makes it possible for a PAM administrator to impersonate the Engine and exfiltrate sensitive information from the messages published in the RabbitMQ exchanges, without being audited in the application. |
| In Delinea PAM Secret Server 11.4, it is possible for an attacker (with Administrator access to the Secret Server machine) to read the following data from a memory dump: the decrypted master key, database credentials (when SQL Server Authentication is enabled), the encryption key of RabbitMQ queue messages, and session cookies. |
| A cryptographic vulnerability exists on Node.js on linux in versions of 18.x prior to 18.40.0 which allowed a default path for openssl.cnf that might be accessible under some circumstances to a non-admin user instead of /etc/ssl as was the case in versions prior to the upgrade to OpenSSL 3. |
| Xiongmai Camera XM-JPR2-LX V4.02.R12.A6420987.10002.147502.00000 is vulnerable to plain-text traffic sniffing. |
| An information exposure vulnerability in Palo Alto Networks PAN-OS software enables a local system administrator to unintentionally disclose secrets, passwords, and tokens of external systems. A read-only administrator who has access to the config log, can read secrets, passwords, and tokens to external systems. |
| SQL injection vulnerability in Jfinalcms v.5.0.0 allows a remote attacker to obtain sensitive information via /admin/admin name parameter. |
| Concrete CMS (formerly concrete5) below 8.5.10 and between 9.0.0 and 9.1.2 inadvertently disclose server-side sensitive information (secrets in environment variables and server information) when Debug Mode is left on in production. |
| A cryptographic vulnerability exists in Node.js <19.2.0, <18.14.1, <16.19.1, <14.21.3 that in some cases did does not clear the OpenSSL error stack after operations that may set it. This may lead to false positive errors during subsequent cryptographic operations that happen to be on the same thread. This in turn could be used to cause a denial of service. |