Export limit exceeded: 417953 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (2536 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-42943 1 Sap 1 Sap Gui 2026-04-15 4.5 Medium
SAP GUI for Windows may allow the leak of NTML hashes when specific ABAP frontend services are called with UNC paths. For a successful attack, the attacker needs developer authorization in a specific Application Server ABAP to make changes in the code, and the victim needs to execute by using SAP GUI for Windows. This could trigger automatic NTLM authentication, potentially exposing hashed credentials to an attacker. As a result, it has a high impact on the confidentiality.
CVE-2025-40265 1 Linux 1 Linux Kernel 2026-04-15 4.1 Medium
In the Linux kernel, the following vulnerability has been resolved: vfat: fix missing sb_min_blocksize() return value checks When emulating an nvme device on qemu with both logical_block_size and physical_block_size set to 8 KiB, but without format, a kernel panic was triggered during the early boot stage while attempting to mount a vfat filesystem. [95553.682035] EXT4-fs (nvme0n1): unable to set blocksize [95553.684326] EXT4-fs (nvme0n1): unable to set blocksize [95553.686501] EXT4-fs (nvme0n1): unable to set blocksize [95553.696448] ISOFS: unsupported/invalid hardware sector size 8192 [95553.697117] ------------[ cut here ]------------ [95553.697567] kernel BUG at fs/buffer.c:1582! [95553.697984] Oops: invalid opcode: 0000 [#1] SMP NOPTI [95553.698602] CPU: 0 UID: 0 PID: 7212 Comm: mount Kdump: loaded Not tainted 6.18.0-rc2+ #38 PREEMPT(voluntary) [95553.699511] Hardware name: QEMU Standard PC (i440FX + PIIX, 1996), BIOS rel-1.16.3-0-ga6ed6b701f0a-prebuilt.qemu.org 04/01/2014 [95553.700534] RIP: 0010:folio_alloc_buffers+0x1bb/0x1c0 [95553.701018] Code: 48 8b 15 e8 93 18 02 65 48 89 35 e0 93 18 02 48 83 c4 10 5b 41 5c 41 5d 41 5e 41 5f 5d 31 d2 31 c9 31 f6 31 ff c3 cc cc cc cc <0f> 0b 90 66 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 90 0f [95553.702648] RSP: 0018:ffffd1b0c676f990 EFLAGS: 00010246 [95553.703132] RAX: ffff8cfc4176d820 RBX: 0000000000508c48 RCX: 0000000000000001 [95553.703805] RDX: 0000000000002000 RSI: 0000000000000000 RDI: 0000000000000000 [95553.704481] RBP: ffffd1b0c676f9c8 R08: 0000000000000000 R09: 0000000000000000 [95553.705148] R10: 0000000000000000 R11: 0000000000000000 R12: 0000000000000001 [95553.705816] R13: 0000000000002000 R14: fffff8bc8257e800 R15: 0000000000000000 [95553.706483] FS: 000072ee77315840(0000) GS:ffff8cfdd2c8d000(0000) knlGS:0000000000000000 [95553.707248] CS: 0010 DS: 0000 ES: 0000 CR0: 0000000080050033 [95553.707782] CR2: 00007d8f2a9e5a20 CR3: 0000000039d0c006 CR4: 0000000000772ef0 [95553.708439] PKRU: 55555554 [95553.708734] Call Trace: [95553.709015] <TASK> [95553.709266] __getblk_slow+0xd2/0x230 [95553.709641] ? find_get_block_common+0x8b/0x530 [95553.710084] bdev_getblk+0x77/0xa0 [95553.710449] __bread_gfp+0x22/0x140 [95553.710810] fat_fill_super+0x23a/0xfc0 [95553.711216] ? __pfx_setup+0x10/0x10 [95553.711580] ? __pfx_vfat_fill_super+0x10/0x10 [95553.712014] vfat_fill_super+0x15/0x30 [95553.712401] get_tree_bdev_flags+0x141/0x1e0 [95553.712817] get_tree_bdev+0x10/0x20 [95553.713177] vfat_get_tree+0x15/0x20 [95553.713550] vfs_get_tree+0x2a/0x100 [95553.713910] vfs_cmd_create+0x62/0xf0 [95553.714273] __do_sys_fsconfig+0x4e7/0x660 [95553.714669] __x64_sys_fsconfig+0x20/0x40 [95553.715062] x64_sys_call+0x21ee/0x26a0 [95553.715453] do_syscall_64+0x80/0x670 [95553.715816] ? __fs_parse+0x65/0x1e0 [95553.716172] ? fat_parse_param+0x103/0x4b0 [95553.716587] ? vfs_parse_fs_param_source+0x21/0xa0 [95553.717034] ? __do_sys_fsconfig+0x3d9/0x660 [95553.717548] ? __x64_sys_fsconfig+0x20/0x40 [95553.717957] ? x64_sys_call+0x21ee/0x26a0 [95553.718360] ? do_syscall_64+0xb8/0x670 [95553.718734] ? __x64_sys_fsconfig+0x20/0x40 [95553.719141] ? x64_sys_call+0x21ee/0x26a0 [95553.719545] ? do_syscall_64+0xb8/0x670 [95553.719922] ? x64_sys_call+0x1405/0x26a0 [95553.720317] ? do_syscall_64+0xb8/0x670 [95553.720702] ? __x64_sys_close+0x3e/0x90 [95553.721080] ? x64_sys_call+0x1b5e/0x26a0 [95553.721478] ? do_syscall_64+0xb8/0x670 [95553.721841] ? irqentry_exit+0x43/0x50 [95553.722211] ? exc_page_fault+0x90/0x1b0 [95553.722681] entry_SYSCALL_64_after_hwframe+0x76/0x7e [95553.723166] RIP: 0033:0x72ee774f3afe [95553.723562] Code: 73 01 c3 48 8b 0d 0a 33 0f 00 f7 d8 64 89 01 48 83 c8 ff c3 0f 1f 84 00 00 00 00 00 f3 0f 1e fa 49 89 ca b8 af 01 00 00 0f 05 <48> 3d 01 f0 ff ff 73 01 c3 48 8b 0d da 32 0f 00 f7 d8 64 89 01 48 [95553.725188] RSP: 002b:00007ffe97148978 EFLAGS: 00000246 ORIG_RAX: 00000000000001af [95553.725892] RAX: ffffffffffffffda RBX: ---truncated---
CVE-2025-37128 2 Arubanetworks, Hp 2 Edgeconnect Enterprise, Arubaos 2026-04-15 6.8 Medium
A vulnerability in the web API of HPE Aruba Networking EdgeConnect SD-WAN Gateways could allow an authenticated remote attacker to terminate arbitrary running processes. Successful exploitation could allow an attacker to disrupt system operations, potentially resulting in an unstable system state.
CVE-2025-25051 1 Automationdirect 1 Click Plc 2026-04-15 6.1 Medium
An attacker could decrypt sensitive data, impersonate legitimate users or devices, and potentially gain access to network resources for lateral attacks.
CVE-2025-24375 2026-04-15 5 Medium
Charmed MySQL K8s operator is a Charmed Operator for running MySQL on Kubernetes. Before revision 221, the method for calling a SQL DDL or python based mysql-shell scripts can leak database users credentials. The method mysql-operator calls mysql-shell application rely on writing to a temporary script file containing the full URI, with user and password. The file can be read by a unprivileged user during the operator runtime, due it being created with read permissions (0x644). On other cases, when calling mysql cli, for one specific case when creating the operator users, the DDL contains said users credentials, which can be leak through the same mechanism of a temporary file. All versions prior to revision 221 for kubernetes and revision 338 for machine operators.
CVE-2025-6894 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in the API authorization logic of the affected device allows an authenticated, low-privileged user to execute the administrative `ping` function, which is restricted to higher-privileged roles. This vulnerability enables the user to perform internal network reconnaissance, potentially discovering internal hosts or services that would otherwise be inaccessible. Repeated exploitation could lead to minor resource consumption. While the overall impact is limited, it may result in some loss of confidentiality and availability on the affected device. There is no impact on the integrity of the device, and the vulnerability does not affect any subsequent systems.
CVE-2025-1394 1 Silabs 1 Emberznet 2026-04-15 N/A
The Ember ZNet stack’s packet buffer manager may read out of bound memory leading to an assert, causing a Denial of Service (DoS).
CVE-2025-23181 2026-04-15 8 High
CWE-250: Execution with Unnecessary Privileges
CVE-2025-23180 2026-04-15 8 High
CWE-250: Execution with Unnecessary Privileges
CVE-2024-8774 2026-04-15 N/A
The SIMPLE.ERP client stores superuser password in a recoverable format, allowing any authenticated SIMPLE.ERP user to escalate privileges to a database administrator. This issue affect SIMPLE.ERP from 6.20 through 6.30. Only the 6.30 version received a patch 6.30@a03.9, which removed the vulnerability. Versions 6.20 and 6.25 remain unpatched.
CVE-2024-5275 1 Fortra 2 Filecatalyst Direct, Filecatalyst Workflow 2026-04-15 7.8 High
A hard-coded password in the FileCatalyst TransferAgent can be found which can be used to unlock the keystore from which contents may be read out, for example, the private key for certificates. Exploit of this vulnerability could lead to a machine-in-the-middle (MiTM) attack against users of the agent. This issue affects all versions of FileCatalyst Direct from 3.8.10 Build 138 and earlier and all versions of FileCatalyst Workflow from 5.1.6 Build 130 and earlier.
CVE-2024-51722 1 Blackberry 1 Secusuite 2026-04-15 6.4 Medium
A local privilege escalation vulnerability in the SecuSUITE Server (System Configuration) of SecuSUITE versions 5.0.420 and earlier could allow a successful attacker that had gained control of code running under one of the system accounts listed in the configuration file to potentially issue privileged script commands.
CVE-2024-51552 1 Abb 3 Aspect Enterprise, Matrix Series, Nexus Series 2026-04-15 6 Medium
Weak password storage vulnerabilities exist in ASPECT if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*.
CVE-2024-43659 2026-04-15 7.2 High
After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).