Export limit exceeded: 417953 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (5098 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2021-26102 | 1 Fortinet | 1 Fortiwan | 2025-01-21 | 9.8 Critical |
| A relative path traversal vulnerability (CWE-23) in FortiWAN version 4.5.7 and below, 4.4 all versions may allow a remote non-authenticated attacker to delete files on the system by sending a crafted POST request. In particular, deleting specific configuration files will reset the Admin password to its default value. | ||||
| CVE-2024-7125 | 2 Hitachi, Linux | 2 Ops Center Common Services, Linux Kernel | 2025-01-21 | 7.8 High |
| Authentication Bypass vulnerability in Hitachi Ops Center Common Services.This issue affects Hitachi Ops Center Common Services: from 10.9.3-00 before 11.0.2-01. | ||||
| CVE-2024-12757 | 2025-01-21 | 8.6 High | ||
| Nedap Librix Ecoreader is missing authentication for critical functions that could allow an unauthenticated attacker to potentially execute malicious code. | ||||
| CVE-2024-51738 | 2025-01-21 | N/A | ||
| Sunshine is a self-hosted game stream host for Moonlight. In 0.23.1 and earlier, Sunshine's pairing protocol implementation does not validate request order and is thereby vulnerable to a MITM attack, potentially allowing an unauthenticated attacker to pair a client by hijacking a legitimate pairing attempt. This bug may also be used by a remote attacker to crash Sunshine. This vulnerability is fixed in 2025.118.151840. | ||||
| CVE-2025-0355 | 2025-01-21 | 7.5 High | ||
| Missing Authentication for Critical Function vulnerability in NEC Corporation Aterm WG2600HS Ver.1.7.2 and earlier, WF1200CRS Ver.1.6.0 and earlier, WG1200CRS Ver.1.5.0 and earlier, GB1200PE Ver.1.3.0 and earlier, WG2600HP4 Ver.1.4.2 and earlier, WG2600HM4 Ver.1.4.2 and earlier, WG2600HS2 Ver.1.3.2 and earlier, WX3000HP Ver.2.4.2 and earlier and WX4200D5 Ver.1.2.4 and earlier allows a attacker to get a Wi-Fi password via the network. | ||||
| CVE-2022-46732 | 1 Ge | 1 Proficy Historian | 2025-01-17 | 9.8 Critical |
| Even if the authentication fails for local service authentication, the requested command could still execute regardless of authentication status. | ||||
| CVE-2024-11639 | 1 Ivanti | 1 Cloud Services Appliance | 2025-01-17 | 10 Critical |
| An authentication bypass in the admin web console of Ivanti CSA before 5.0.3 allows a remote unauthenticated attacker to gain administrative access | ||||
| CVE-2023-1837 | 1 Hypr | 1 Hypr Server | 2025-01-17 | 8.5 High |
| Missing Authentication for critical function vulnerability in HYPR Server allows Authentication Bypass when using Legacy APIs.This issue affects HYPR Server: before 8.0 (with enabled Legacy APIs) | ||||
| CVE-2024-9137 | 1 Moxa | 7 Edf-g1002-bp, Edr-8010, Edr-g9004 and 4 more | 2025-01-17 | 9.4 Critical |
| The affected product lacks an authentication check when sending commands to the server via the Moxa service. This vulnerability allows an attacker to execute specified commands, potentially leading to unauthorized downloads or uploads of configuration files and system compromise. | ||||
| CVE-2023-0052 | 1 Sauter-controls | 10 Modunet300 Ey-am300f001, Modunet300 Ey-am300f001 Firmware, Modunet300 Ey-am300f002 and 7 more | 2025-01-16 | 9.8 Critical |
| SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol (FTP) are the only protocols available for device management, an unauthorized user could access the system and modify the device configuration, which could result in the unauthorized user executing unrestricted malicious commands. | ||||
| CVE-2023-24020 | 1 Snapav | 2 Wattbox Wb-300-ip-3, Wattbox Wb-300-ip-3 Firmware | 2025-01-16 | 7.5 High |
| Snap One Wattbox WB-300-IP-3 versions WB10.9a17 and prior could bypass the brute force protection, allowing multiple attempts to force a login. | ||||
| CVE-2023-0102 | 1 Ls-electric | 2 Xbc-dn32u, Xbc-dn32u Firmware | 2025-01-16 | 9.1 Critical |
| LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication for its deletion command. This could allow an attacker to delete arbitrary files. | ||||
| CVE-2023-22803 | 1 Ls-electric | 2 Xbc-dn32u, Xbc-dn32u Firmware | 2025-01-16 | 7.5 High |
| LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to perform critical functions to the PLC. This could allow an attacker to change the PLC's mode arbitrarily. | ||||
| CVE-2023-22804 | 1 Ls-electric | 2 Xbc-dn32u, Xbc-dn32u Firmware | 2025-01-16 | 9.1 Critical |
| LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device. | ||||
| CVE-2023-1140 | 1 Deltaww | 1 Infrasuite Device Master | 2025-01-16 | 9.8 Critical |
| Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator. | ||||
| CVE-2023-36497 | 1 Doverfuelingsolutions | 2 Maglink Lx 3, Maglink Lx Web Console Configuration | 2025-01-16 | 8.8 High |
| Dover Fueling Solutions MAGLINK LX Web Console Configuration versions 2.5.1, 2.5.2, 2.5.3, 2.6.1, 2.11, 3.0, 3.2, and 3.3 could allow a guest user to elevate to admin privileges. | ||||
| CVE-2023-42769 | 1 Sielco | 30 Analog Fm Transmitter Exc1000gt, Analog Fm Transmitter Exc1000gt Firmware, Analog Fm Transmitter Exc1000gx and 27 more | 2025-01-16 | 9.8 Critical |
| The cookie session ID is of insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session, bypass authentication, and manipulate the transmitter. | ||||
| CVE-2023-5754 | 1 Sielco | 6 Polyeco1000, Polyeco1000 Firmware, Polyeco300 and 3 more | 2025-01-16 | 9.1 Critical |
| Sielco PolyEco1000 uses a weak set of default administrative credentials that can be easily guessed in remote password attacks and gain full control of the system. | ||||
| CVE-2023-32074 | 1 Nextcloud | 1 User Oidc | 2025-01-16 | 8 High |
| user_oidc app is an OpenID Connect user backend for Nextcloud. Authentication can be broken/bypassed in user_oidc app. It is recommended that the Nextcloud user_oidc app is upgraded to 1.3.2 | ||||
| CVE-2024-34077 | 1 Mantisbt | 1 Mantisbt | 2025-01-16 | 7.3 High |
| MantisBT (Mantis Bug Tracker) is an open source issue tracker. Insufficient access control in the registration and password reset process allows an attacker to reset another user's password and takeover their account, if the victim has an incomplete request pending. The exploit is only possible while the verification token is valid, i.e for 5 minutes after the confirmation URL sent by e-mail has been opened, and the user did not complete the process by updating their password. A brute-force attack calling account_update.php with increasing user IDs is possible. A successful takeover would grant the attacker full access to the compromised account, including sensitive information and functionalities associated with the account, the extent of which depends on its privileges and the data it has access to. Version 2.26.2 contains a patch for the issue. As a workaround, one may mitigate the risk by reducing the verification token's validity (change the value of the `TOKEN_EXPIRY_AUTHENTICATED` constant in `constants_inc.php`). | ||||