| A vulnerability has been identified in SICAM SIAPP SDK (All versions < V2.1.7). The SICAM SIAPP SDK does not perform checks on input values potentially resulting in stack overflow. This could allow an attacker to perform code execution and denial of service. |
| A vulnerability has been identified in SICAM SIAPP SDK (All versions < V2.1.7). The affected application builds shell commands with caller-provided strings and executes them. An attacker could influence the executed command, potentially resulting in command injection and full system compromise. |
| A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application leaks confidential information in metadata, and files such as information on contributors and email address, on `SSM Server`. |
| ppd in Reliant Sinix allows local users to corrupt arbitrary files via a symlink attack in the /tmp/ppd.trace file. |
| FTP servers can allow an attacker to connect to arbitrary ports on machines other than the FTP client, aka FTP bounce. |
| Siemens SpeedStream 2624 allows remote attackers to cause a denial of service (device hang) by sending a crafted packet to the web administrative interface. |
| Siemens Speedstream Wireless Router 2624 allows local users to bypass authentication and access protected files by using the Universal Plug and Play UPnP/1.0 component. |
| DB4Web server, when configured to use verbose debug messages, allows remote attackers to use DB4Web as a proxy and attempt TCP connections to other systems (port scan) via a request for a URL that specifies the target IP address and port, which produces a connection status in the resulting error message. |
| The management interface for Siemens SANTIS 50 running firmware 4.2.8.0, and possibly other products including Ericsson HN294dp and Dynalink RTA300W, allows remote attackers to access the Telnet port without authentication via certain packets to the web interface that cause the interface to freeze. |
| GUI overlay vulnerability in the Java API in Siemens S55 cellular phones allows remote attackers to send unauthorized SMS messages by overlaying a confirmation message with a malicious message. |
| Siemens 3568i WAP mobile phones allows remote attackers to cause a denial of service (crash) via an SMS message containing unusual characters. |
| Buffer overflow in Siemens 45 series mobile phones allows remote attackers to cause a denial of service (disconnect and unavailable inbox) via a Short Message Service (SMS) message with a long image name. |
| Reliant Unix 5.44 and earlier allows remote attackers to cause a denial of service via an ICMP port unreachable packet, which causes Reliant to drop all connections to the source address of the packet. |
| Buffer overflow in the web administration service for the HiNet LP5100 IP-phone allows remote attackers to cause a denial of service and possibly execute arbitrary commands via a long GET request. |
| OpenSSH-portable (OpenSSH) 3.6.1p1 and earlier with PAM support enabled immediately sends an error message when a user does not exist, which allows remote attackers to determine valid usernames via a timing attack. |
| libcurl versions from 7.36.0 to before 7.64.0 is vulnerable to a heap buffer out-of-bounds read. The function handling incoming NTLM type-2 messages (`lib/vauth/ntlm.c:ntlm_decode_type2_target`) does not validate incoming data correctly and is subject to an integer overflow vulnerability. Using that overflow, a malicious or broken NTLM server could trick libcurl to accept a bad length + offset combination that would lead to a buffer read out-of-bounds. |
| libcurl versions from 7.36.0 to before 7.64.0 are vulnerable to a stack-based buffer overflow. The function creating an outgoing NTLM type-3 header (`lib/vauth/ntlm.c:Curl_auth_create_ntlm_type3_message()`), generates the request HTTP header contents based on previously received data. The check that exists to prevent the local buffer from getting overflowed is implemented wrongly (using unsigned math) and as such it does not prevent the overflow from happening. This output data can grow larger than the local buffer if very large 'nt response' data is extracted from a previous NTLMv2 header provided by the malicious or broken HTTP server. Such a 'large value' needs to be around 1000 bytes or more. The actual payload data copied to the target buffer comes from the NTLMv2 type-2 response header. |
| A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP3), User Management Component (UMC) (All versions < V2.15.2.1). The affected application permits improper modification of a configuration file by a low-privileged user.
This could allow an attacker to load malicious DLLs, potentially leading to arbitrary code execution with SYSTEM privileges.(ZDI-CAN-28108) |
| A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x IP6 (All versions), Cerberus PRO EN Fire Panel FC72x IP7 (All versions), Cerberus PRO EN Fire Panel FC72x IP8 (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.3.5617), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions), Sinteso FS20 EN Fire Panel FC20 MP8 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems insufficiently validates HMAC values which might result in a buffer overread.
This could allow an unauthenticated remote attacker to crash the network service. |
| A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), JT Bi-Directional Translator for STEP (All versions), NX V2412 (All versions < V2412.8900 with Cloud Entitlement (bundled as NX X)), NX V2506 (All versions < V2506.6000 with Cloud Entitlement (bundled as NX X)), Simcenter 3D (All versions < V2506.6000 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Femap (All versions < V2506.0002 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Studio (All versions < V2506.0001), Simcenter System Architect (All versions < V2506.0001), Tecnomatix Plant Simulation (All versions < V2504.0007). The SALT SDK is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack. |