| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Smart Slider 3 Pro version 3.5.1.35 for WordPress and Joomla contains a multi-stage remote access toolkit injected through a compromised update system that allows unauthenticated attackers to execute arbitrary code and commands. Attackers can trigger pre-authentication remote shell execution via HTTP headers, establish authenticated backdoors accepting arbitrary PHP code or OS commands, create hidden administrator accounts, exfiltrate credentials and access keys, and maintain persistence through multiple injection points including must-use plugins and core file modifications. |
| Epross AVCON6 systems management platform contains an object-graph navigation language (OGNL) injection vulnerability that allows unauthenticated attackers to execute arbitrary commands by injecting malicious OGNL expressions. Attackers can send crafted requests to the login.action endpoint with OGNL payloads in the redirect parameter to instantiate ProcessBuilder objects and execute system commands with root privileges. |
| NetGain EM Plus 10.1.68 contains a remote code execution vulnerability that allows unauthenticated attackers to execute arbitrary system commands by submitting malicious parameters to the script_test.jsp endpoint. Attackers can send POST requests with shell commands embedded in the 'content' parameter to execute code and retrieve command output. |
| An Authentication Bypass Using an
Alternate Path or Channel vulnerability in Juniper Networks Session Smart
Router may allows a network-based attacker to bypass authentication
and take administrative control of the device.
This issue affects Session Smart Router:
* from 5.6.7 before 5.6.17,
* from 6.0 before 6.0.8 (affected from 6.0.8),
* from 6.1 before 6.1.12-lts,
* from 6.2 before 6.2.8-lts,
* from 6.3 before 6.3.3-r2;
This issue affects Session Smart Conductor:
* from 5.6.7 before 5.6.17,
* from 6.0 before 6.0.8 (affected from 6.0.8),
* from 6.1 before 6.1.12-lts,
* from 6.2 before 6.2.8-lts,
* from 6.3 before 6.3.3-r2;
This issue affects WAN Assurance Managed Routers:
* from 5.6.7 before 5.6.17,
* from 6.0 before 6.0.8 (affected from 6.0.8),
* from 6.1 before 6.1.12-lts,
* from 6.2 before 6.2.8-lts,
* from 6.3 before 6.3.3-r2. |
| Wasmtime is a runtime for WebAssembly. From 32.0.0 to before 36.0.7, 42.0.2, and 43.0.1, Wasmtime's Cranelift compilation backend contains a bug on aarch64 when performing a certain shape of heap accesses which means that the wrong address is accessed. When combined with explicit bounds checks a guest WebAssembly module this can create a situation where there are two diverging computations for the same address: one for the address to bounds-check and one for the address to load. This difference in address being operated on means that a guest module can pass a bounds check but then load a different address. Combined together this enables an arbitrary read/write primitive for guest WebAssembly when accesssing host memory. This is a sandbox escape as guests are able to read/write arbitrary host memory. This vulnerability has a few ingredients, all of which must be met, for this situation to occur and bypass the sandbox restrictions. This miscompiled shape of load only occurs on 64-bit WebAssembly linear memories, or when Config::wasm_memory64 is enabled. 32-bit WebAssembly is not affected. Spectre mitigations or signals-based-traps must be disabled. When spectre mitigations are enabled then the offending shape of load is not generated. When signals-based-traps are disabled then spectre mitigations are also automatically disabled. The specific bug in Cranelift is a miscompile of a load of the shape load(iadd(base, ishl(index, amt))) where amt is a constant. The amt value is masked incorrectly to test if it's a certain value, and this incorrect mask means that Cranelift can pattern-match this lowering rule during instruction selection erroneously, diverging from WebAssembly's and Cranelift's semantics. This incorrect lowering would, for example, load an address much further away than intended as the correct address's computation would have wrapped around to a smaller value insetad. This vulnerability is fixed in 36.0.7, 42.0.2, and 43.0.1. |
| Wasmtime is a runtime for WebAssembly. From 25.0.0 to before 36.0.7, 42.0.2, and 43.0.1, Wasmtime with its Winch (baseline) non-default compiler backend may allow properly constructed guest Wasm to access host memory outside of its linear-memory sandbox. This vulnerability requires use of the Winch compiler (-Ccompiler=winch). By default, Wasmtime uses its Cranelift backend, not Winch. With Winch, the same incorrect assumption is present in theory on both aarch64 and x86-64. The aarch64 case has an observed-working proof of concept, while the x86-64 case is theoretical and may not be reachable in practice. This Winch compiler bug can allow the Wasm guest to access memory before or after the linear-memory region, independently of whether pre- or post-guard regions are configured. The accessible range in the initial bug proof-of-concept is up to 32KiB before the start of memory, or ~4GiB after the start of memory, independently of the size of pre- or post-guard regions or the use of explicit or guard-region-based bounds checking. However, the underlying bug assumes a 32-bit memory offset stored in a 64-bit register has its upper bits cleared when it may not, and so closely related variants of the initial proof-of-concept may be able to access truly arbitrary memory in-process. This could result in a host process segmentation fault (DoS), an arbitrary data leak from the host process, or with a write, potentially an arbitrary RCE. This vulnerability is fixed in 36.0.7, 42.0.2, and 43.0.1. |
| The firmware in KAON CG3000TC and CG3000T routers contains hard-coded credentials in clear text (shared across all routers of this model) that an unauthenticated remote attacker could use to execute commands with root privileges.
This vulnerability has been fixed in firmware version: 1.00.67 for CG3000TC and 1.00.27 for CG3000T. |
| After receiving a
malformed 802.15.4 MAC Data Request
the Zigbee Coordinator sends a ‘network leave’ request to Zigbee router resulting in the Zigbee Router getting stuck in a non-rejoinable state. If a suitable parent is not available, the end devices will be unable to rejoin. A manual recommissioning is required to recover the Zigbee Router. |
| Forgejo before 13.0.2 allows attackers to write to unintended files, and possibly obtain server shell access, because of mishandling of out-of-repository symlink destinations for template repositories. This is also fixed for 11 LTS in 11.0.7 and later. |
| An untrusted search path vulnerability has been identified in the Embedded Solutions Framework in various Lexmark devices. This vulnerability can be leveraged by an attacker to execute arbitrary code. |
| A vulnerability in Nuvation Battery Management System allows Authentication Bypass.This issue affects Battery Management System: through 2.3.9. |
| A vulnerability in Nuvation Energy nCloud VPN Service allowed Network Boundary Bridging.This issue affected the nCloud VPN Service and was fixed on 2025-12-1 (December, 2025). End users do not have to take any action to mitigate the issue. |
| Sites running NOAA PMEL Live Access Server (LAS) are vulnerable to remote code execution via specially crafted requests that include PyFerret expressions. By leveraging a SPAWN command, a remote, unauthenticated attacker can execute arbitrary OS commands. Fixed in a version of 'gov.noaa.pmel.tmap.las.filter.RequestInputFilter.java' from 2025-09-24. |
| On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards. |
| Multiple hardcoded credentials have been identified, which are allowed to sign-in to the exos 9300 datapoint server running on port 1004 and 1005. This server is used for relaying status information from and to the Access Managers. This information, among other things, is used to graphically visualize open doors and alerts. However, controlling the Access Managers via this interface is also possible.
To send and receive status information, authentication is necessary. The Kaba exos 9300 application contains hard-coded credentials for four different users, which are allowed to login to the datapoint server and receive as well as send information, including commands to open arbitrary doors. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| The Access Manager 92xx in hardware revision K7 is based on Linux instead of Windows CE embedded in older hardware revisions. In this new hardware revision it was noticed that an SSH service is exposed on port 22. By analyzing the firmware of the devices, it was noticed that there are two users with hardcoded and weak passwords that can be used to access the devices via SSH. The passwords can be also guessed very easily. The password of at least one user is set to a random value after the first deployment, with the restriction that the password is only randomized if the configured date is prior to 2022. Therefore, under certain circumstances, the passwords are not randomized. For example, if the clock is never set on the device, the battery of the clock module has been changed, the Access Manager has been factory reset and has not received a time yet. |
| By default, the password for the Access Manager's web interface, is set to 'admin'. In the tested version changing the password was not enforced. |
| SQL injection vulnerability in Infoticketing. This vulnerability allows
an unauthenticated attacker to retrieve, create, update, and delete the
database by sending a POST request using the 'code' parameter in '/components/cart/cartApplyDiscount.php'. |
| Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has learned the identity of a legitimate user. |