| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device. |
| SiRcom SMART Alert (SiSA) allows unauthorized access to backend APIs. This allows an unauthenticated attacker to bypass the login screen using browser developer tools, gaining access to restricted parts of the application. |
| The Iskra iHUB and iHUB Lite smart metering gateway exposes its web management interface without requiring authentication, allowing unauthenticated users to access and modify critical device settings. |
| A malicious actor can access camera configuration information, including account credentials, without authenticating when accessing a vulnerable URL. |
| Incorrect Implementation of Authentication Algorithm vulnerability in ABB ABB Ability OPTIMAX.This issue affects ABB Ability OPTIMAX: 6.1, 6.2, from 6.3.0 before 6.3.1-251120, from 6.4.0 before 6.4.1-251120. |
| NVIDIA Isaac Lab contains a vulnerability in SB3 configuration parsing. A successful exploit of this vulnerability might lead to code execution, denial of service, escalation of privileges, information disclosure, or data tampering. |
| The OTP Integration Kit for PingFederate fails to enforce HTTP method validation and state validation properly. The server advances the authentication state without verifying the OTP, thereby bypassing multi-factor authentication. |
| Sensitive data disclosure and manipulation due to missing authentication. The following products are affected: Acronis Cyber Protect Cloud Agent (Linux, macOS, Windows) before build 39870, Acronis Cyber Protect 16 (Linux, macOS, Windows) before build 39938, Acronis Cyber Protect 15 (Linux, macOS, Windows) before build 41800. |
| There is a misconfiguration vulnerability inside the Infotainment ECU manufactured by BOSCH. The vulnerability happens during the startup phase of a specific systemd service, and as a result, the following developer features will be activated: the disabled firewall and the launched SSH server.
First identified on Nissan Leaf ZE1 manufactured in 2020. |
| The database for the web application is exposed without authentication, allowing an unauthenticated remote attacker to gain unauthorized access and potentially compromise it. |
| The web application allows an unauthenticated remote attacker to learn information about existing user accounts with their corresponding role due to missing authentication for critical function. |
| A low-privileged local attacker can exploit improper permissions on nssm.exe to escalate their privileges and gain administrative access. |
| An unauthenticated remote attacker can get access without password protection to the affected device. This enables the unprotected read-only access to the stored measurement data. |
| An unauthenticated remote attacker can cause a Denial of Service by turning off the output of the UPS via Modbus command. |
| KuWFi CPF908-CP5 WEB5.0_LCD_20210125 devices have multiple unauthenticated access control vulnerabilities within goform/goform_set_cmd_process and goform/goform_get_cmd_process. These allow an unauthenticated attacker to retrieve sensitive information (including the device admin username and password), modify critical device settings, and send arbitrary SMS messages. |
| Incorrect Implementation of Authentication Algorithm vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K. |
| A vulnerability exists in the NodeRestriction admission controller in Kubernetes clusters where node users can delete their corresponding node object by patching themselves with an OwnerReference to a cluster-scoped resource. If the OwnerReference resource does not exist or is subsequently deleted, the given node object will be deleted via garbage collection. |
| Soosyze CMS 2.0 allows brute-force login attacks via the /user/login endpoint due to missing rate-limiting and lockout mechanisms. An attacker can repeatedly submit login attempts without restrictions, potentially gaining unauthorized administrative access. This vulnerability corresponds to CWE-307: Improper Restriction of Excessive Authentication Attempts. |
| E2 Facility Management Systems use a proprietary protocol that allows for unauthenticated file operations on any file in the file system. |
| Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 in order to allow
management operations on the device such as firmware upgrades and device
reboot requiring an authentication. A wrong management of login
failures of the service allows a denial-of-service attack, leaving the telnet service
into an unreachable state. |