| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Open-Xchange AppSuite 7.0.x before 7.0.2-rev15 and 7.2.x before 7.2.2-rev16 has a hardcoded password for node join operations, which allows remote attackers to expand a cluster by finding this password in the source code and then sending the password in a Hazelcast cluster API call, a different vulnerability than CVE-2013-5200. |
| Microsoft Dynamics GP has a default value of ACCESS for the system password, which might make it easier for remote authenticated users to bypass intended access restrictions via unspecified vectors. |
| Moxa IKS and EDS store plaintext passwords, which may allow sensitive information to be read by someone with access to the device. |
| weblogin/login.fcgi (aka the WebLogin login script) in Stanford University WebAuth 3.5.5, 3.6.0, and 3.6.1 places passwords in URLs in certain circumstances involving conversion of a POST request to a GET request, which allows context-dependent attackers to discover passwords by reading (1) web-server access logs, (2) web-server Referer logs, or (3) the browser history. |
| The LDAP authentication feature in XLight FTP Server before 2.83, when used with some unspecified LDAP servers, does not check for blank passwords, which allows remote attackers to bypass intended access restrictions. |
| A vulnerability was discovered in all versions of Medtronic MyCareLink 24950 and 24952 Patient Monitor. The affected products use per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication and encryption of local data at rest. |
| Dell EMC OpenManage Integration for Microsoft System Center (OMIMSSC) for SCCM and SCVMM versions prior to 7.2.1 contain a hard-coded cryptographic key vulnerability. A remote unauthenticated attacker may exploit this vulnerability to gain access to the appliance data for remotely managed devices. |
| EMC VPLEX before VPLEX GeoSynchrony 5.2 SP1 uses cleartext for storage of the LDAP/AD bind password, which allows local users to obtain sensitive information by reading the management-server configuration file. |
| Gyach Enhanced (Gyach-E) before 1.0.0 stores passwords in plaintext, which allows attackers to obtain user passwords by reading the configuration file. |
| The Add Member dialog in the Security admin page in SilverStripe 2.4.0 saves user passwords in plaintext, which allows local users to obtain sensitive information by reading a database. |
| hydra.exe in HP SAN/iQ before 9.5 on the HP Virtual SAN Appliance has a hardcoded password of L0CAlu53R for the global$agent account, which allows remote attackers to obtain access to a management service via a login: request to TCP port 13838. |
| A vulnerability in generate_filestorage_key of Ubuntu MAAS allows an attacker to brute-force filenames. This issue affects Ubuntu MAAS versions prior to 1.9.2. |
| In Android before 2018-04-05 or earlier security patch level on Qualcomm Snapdragon Automobile, Snapdragon Mobile, and Snapdragon Wear MDM9206, MDM9607, MDM9635M, MDM9640, MDM9645, MDM9650, MSM8909W, SD 210/SD 212/SD 205, SD 410/12, SD 425, SD 430, SD 450, SD 615/16/SD 415, SD 617, SD 625, SD 650/52, SD 808, SD 810, SD 820, SD 820A, SD 835, SD 845, and SD 850, packet replay may be possible. |
| A flaw was found in the libssh implements abstract layer for message digest (MD) operations implemented by different supported crypto backends. The return values from these were not properly checked, which could cause low-memory situations failures, NULL dereferences, crashes, or usage of the uninitialized memory as an input for the KDF. In this case, non-matching keys will result in decryption/integrity failures, terminating the connection. |
| HCL Launch stores user credentials in plain clear text which can be read by a local user. |
| Verbatim Corporate Secure and Corporate Secure FIPS Edition USB flash drives do not prevent password replay attacks, which allows physically proximate attackers to access the cleartext drive contents by providing a key that was captured in a USB data stream at an earlier time. |
| The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request. |
| The Emerson Process Management ROC800 RTU with software 3.50 and earlier, DL8000 RTU with software 2.30 and earlier, and ROC800L RTU with software 1.20 and earlier have hardcoded credentials in a ROM, which makes it easier for remote attackers to obtain shell access to the underlying OS by leveraging knowledge of the ROM contents from a product installation elsewhere. |
| Use of MAC address as an authenticated password in QSAN Storage Manager, XEVO, SANOS allows local attackers to escalate privileges. Suggest contacting with QSAN and refer to recommendations in QSAN Document. |
| The "Lost Password" reset functionality in ownCloud before 4.0.9 and 4.5.0 does not properly check the security token, which allows remote attackers to change an accounts password via unspecified vectors related to a "Remote Timing Attack." |